Standard to Custom

When you want to solve a control problem fast with minimal engineering time, Applied Products are pre-configured, pre-programmed solutions based on Divelbiss standard hardware, ready to wire, configure, and run. Many include software you can tweak later.

What you gain: 

  • Speed to deployment: manuals, wiring diagrams, and often editable software are included.

  • Lower risk: field-tested logic built on standard platforms.

  • Room to customize as needs evolve.

s-l1200 (1) ef580c8046fa4e08b32158871b37b964 s-l400

Mobile
Machinery

Outdoor/Field
Equipment

Harsh Industrial
Zones

Ideal for: common control tasks (e.g., timing, counting, pump alternating, tachometer, analog deadband) where you want proven logic out-of-the-box.

MODELDigital Inputs/OutputsCounter InputsAnalog Input/OutputsCAN Port(s)Serial Port(s)Ethernet / Wi-Fi

  • DC Power & I/O
  • 12 Digital Inputs / 8 Digital Outputs (PWM Capable)
  • 7 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • 1 Analog Output, 0-10VDC/0-20mADC (10 bit)
  • 3 High Speed Counter Inputs, 100KHz Max.
  • 1 Serial Port, RS232 (Modbus Master/Slave)
  • 1 Serial Port, RS485 (Modbus Master/Slave)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
    VBDSP Port for VBDSP-XX Display board (Display/Keypad option)
  • Expansion Port for VB2X
  • Expansions (Digital I/O, Thermocouple Inputs, Cellular Data)
    Extended Operating Temperature range
  • DC Power & I/O
  • 12 Digital Inputs / 8 Digital Outputs (PWM Capable)
  • 7 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • 1 Analog Output, 0-10VDC/0-20mADC (10 bit)
  • 3 High Speed Counter Inputs, 100KHz Max.
  • Ethernet (Modbus TCP)
  • 1 Serial Port, RS232 (Modbus Master/Slave)
  • 1 Serial Port, RS485 (Modbus Master/Slave)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • VBDSP Port for VBDSP-XX Display board (Display/Keypad option)
  • Expansion Port for VB2X Expansions (Digital I/O, Thermocouple Inputs, Cellular Data)
  • Extended Operating Temperature range
  • DC Power & I/O
  • 12 Digital Inputs / 8 Digital Outputs (PWM Capable)
  • 7 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • 1 Analog Output, 0-10VDC/0-20mADC (10 bit)
  • 3 High Speed Counter Inputs, 100KHz Max.
  • Wi-Fi (Modbus TCP)
  • 1 Serial Port, RS232 (Modbus Master/Slave)
  • 1 Serial Port, RS485 (Modbus Master/Slave)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • VBDSP Port for VBDSP-XX Display board (Display/Keypad option)
  • Expansion Port for VB2X Expansions (Digital I/O, Thermocouple Inputs, Cellular Data)
  • Extended Operating Temperature range
  • DC Power & I/O
  • 12 Digital Inputs / 8 Digital Outputs (PWM Capable)
  • 7 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • 1 Analog Output, 0-10VDC/0-20mADC (10 bit)
  • 3 High Speed Counter Inputs, 100KHz Max.
  • Ethernet (Modbus TCP)
  • 1 Serial Port, RS232 (Modbus Master/Slave)
  • 1 Serial Port, RS485 (Modbus Master/Slave)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • LCD and Keypad Port for Parallel LCD and Matrix keypad
  • Expansion Port for VB2X Expansions (Digital I/O, Thermocouple Inputs, Cellular Data)
  • Extended Operating Temperature range
  • DC Power & I/O
  • 8 Digital Inputs / 8 Digital Outputs (Expandable using ICM-IO-CXX Expanders)
    up to 8 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
    up to 1 Analog Output, 0-10VDC/0-10VDC (10 bit)
  • Ethernet (Modbus TCP)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • LCD and Keypad Port for Parallel LCD and Matrix keypad
  • Expansion Port for BB-P13 Expansions (Cellular Data, GPS)
  • Extended Operating Temperature range
  • DC Power & I/O
  • 8 Digital Inputs / 8 Digital Outputs (Expandable using ICM-IO-CXX Expanders)
  • up to 8 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • up to 1 Analog Output, 0-10VDC/0-10VDC (10 bit)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • LCD and Keypad Port for Parallel LCD and Matrix keypad
  • Expansion Port for BB-P13 Expansions (Cellular Data, GPS, Wi-Fi)
  • Extended Operating Temperature range
  • AC Power & I/O
  • 8 Digital Inputs / 8 Digital Outputs (Expandable using ICM-IO-CXX Expanders)
  • up to 8 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • up to 1 Analog Output, 0-10VDC/0-10VDC (10 bit)
  • Ethernet (Modbus TCP)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • LCD and Keypad Port for Parallel LCD and Matrix keypad
  • Expansion Port for BB-P13 Expansions (Cellular Data, GPS)
  • Extended Operating Temperature range
  • AC Power & I/O
  • 8 Digital Inputs / 8 Digital Outputs (Expandable using ICM-IO-CXX Expanders)
  • up to 8 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (12 bit)
  • up to 1 Analog Output, 0-10VDC/0-10VDC (10 bit)
  • 1 CAN Port, J1939 Read/Write, NMEA 2000
  • LCD and Keypad Port for Parallel LCD and Matrix keypad
  • Expansion Port for BB-P13 Expansions (Cellular Data, GPS, Wi-Fi)
  • Extended Operating Temperature range
  • DC Power & I/O
  • 12 Digital Inputs / 8 Digital Outputs (PWM Capable)
  • 7 Analog Inputs, 0-5VDC/0-10VDC/0-20mADC (10 bit)
  • 2 High Speed Counter Inputs, 100KHz Max.
  • 1 Serial Port, RS232 (Modbus Slave)
  • 2 CAN Ports, J1939 Read
  • Expansion Port for VBEX Expansions (Digital I/O, Thermocouple Inputs)
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • High Speed Counter Input, 100KHz Max.
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • High Speed Counter Input, 100KHz Max.
  • Real Time Clock
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • High Speed Counter Input, 100KHz Max.
  • Real Time Clock
  • EBB I/O Expansion Port for ICM-EBB-IO54RE-P Expander
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • High Speed Counter Input, 100KHz Max.
  • Real Time Clock
  • High Density I/O (HDIO) Expansion Port for High Density I/O Expander Boards
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • 1 High Speed Counter Input, 100KHz Max.
  • Real Time Clock
  • 1 CAN Port – J1939 Read Only
  • 1 Serial Port Header – for RS232/RS422/RS485 Serial Port Module
  • EBB I/O Expansion Port for ICM-EBB-IO54RE-P Expander
  • AC or DC Power & I/O
  • 5 Digital Inputs / 5 Relay Outputs
  • 1 High Speed Counter Input, 100KHz Max.
  • Real Time Clock
  • 1 CAN Port – J1939 Read Only
  • 1 Serial Port Header – for RS232/RS422/RS485 Serial Port Module
  • High Density I/O (HDIO) Expansion Port for High Density I/O Expander Boards
  • DC Power & I/O
  • 6 Digital Inputs / 4 Relay Outputs (2 DPDT 2A, 2 Form C 5A)
  • 1 High Speed Counter Input, 25KHz Max.
  • 1 Analog Input, 0-5VDC (10 bit)
  • DC Power & I/O
  • 6 Digital Inputs / 4 Relay Outputs (2 DPDT 2A, 2 Form C 5A)
  • 1 High Speed Counter Input, 25KHz Max.
  • 2 Analog Inputs, 0-5VDC (10 bit)
  • 4 Digit, 7-Segment Display
  • 3 Programmable Push Buttons

* Requires Plug in Module

Contact Us
First
Last

Contact US

standard-quality-control